Teck Connector Size Chart: A Comprehensive Guide (T&B)

Navigating T&B’s Teck connector offerings requires understanding cable and hub sizes, detailed in readily available PDF documentation. This guide simplifies selection, referencing CSA and UL specifications.

Teck connectors, manufactured by T&B, are essential components for terminating and securing Type Teck cable – a robust, metal-clad cable commonly utilized in demanding industrial and outdoor applications. These connectors provide a weatherproof seal, safeguarding electrical connections against moisture, corrosion, and physical damage. Understanding the nuances of Teck connector sizing is paramount for ensuring a secure and reliable installation.

The selection process hinges on accurately matching the connector’s hub size to the cable’s outer diameter. T&B provides comprehensive PDF documentation, including detailed size charts, to facilitate this process. These charts outline the compatible cable sizes for each connector, categorized by cable type (e.g., 14/8, 14/10, 12 AWG). Proper selection guarantees strain relief and maintains the cable’s integrity, adhering to stringent CSA and UL specifications. Ignoring these guidelines can compromise safety and performance.

What is Teck Cable?

Teck cable, also known as MC (Metal-Clad) cable, is a durable, factory-assembled cable featuring conductors insulated with polyethylene, enveloped within a metallic sheath – typically aluminum – for superior protection. This construction renders it ideal for harsh environments, direct burial applications, and locations demanding resistance to physical impact and moisture. It’s commonly found in industrial settings, outdoor installations, and hazardous locations.

Understanding Teck cable’s construction is crucial when selecting the appropriate T&B connector. The cable’s outer diameter dictates the necessary hub size, detailed in T&B’s readily available PDF documentation and size charts. These charts, often referenced alongside CSA C22.2 No. 18 specifications, provide precise guidance. Variations exist, like Star Teck and Star Teck XP, influencing connector compatibility. Correct pairing, as outlined in the PDF, ensures a watertight seal and maintains cable integrity.

Understanding T&B Teck Connectors

T&B (Thomas & Betts) Teck connectors are engineered to provide secure, reliable terminations for Teck cable, safeguarding against environmental factors and maintaining electrical integrity. These connectors, detailed in comprehensive PDF catalogs, come in various materials – including metallic and non-metallic options – to suit diverse application needs. Key considerations include hub size, gland size, and compatibility with specific Teck cable constructions like Star Teck and Star Teck XP.

The T&B size charts, accessible as PDF downloads, are essential for proper selection. They correlate cable dimensions with appropriate connector trade sizes (1/2″ to 4″). Understanding the overlapping size ranges allows accommodation of slight variations in cable diameters. Referencing UL File E 23018 and CSA standards (C22.2 No. 18) within the PDF ensures compliance and safe installation.

Teck Connector Size Charts – Key Considerations

Accurate Teck connector selection, detailed in T&B’s PDF charts, hinges on cable size, hub compatibility, and understanding Star Teck versus XP variations.

Cable Size and Connector Compatibility

Ensuring proper connector compatibility with your Teck cable size is paramount for a secure and reliable installation. T&B provides comprehensive PDF charts detailing these crucial relationships. These charts correlate specific cable gauges – such as 14/8, 14/10, and 12 AWG – with corresponding hub sizes and connector styles (Star Teck and Star Teck XP).

The PDF documentation highlights that suggested cable sizes can vary slightly depending on the cable manufacturer’s specifications. Therefore, always cross-reference the cable’s outer jacket diameter with the connector’s listed accommodation range. Utilizing the incorrect connector size can compromise the cable’s environmental protection and potentially lead to system failures. Careful attention to these details, guided by the T&B PDF resources, is essential for a successful and compliant installation.

Remember to consider the overlapping size ranges offered by Star Teck fittings, designed to accommodate a broad spectrum of cables, simplifying inventory management and installation flexibility.

Hub Size and Gland Size Relationship

T&B’s Teck connector PDF charts meticulously outline the relationship between hub size and gland size, critical for achieving a watertight seal. The hub size, typically expressed in trade sizes (1/2″ to 4″), dictates the overall connector dimensions, while the gland size determines the cable entry point.

These charts demonstrate how specific hub sizes accommodate varying gland sizes, ensuring a secure grip on the cable jacket. For instance, a 1/2″ hub might feature a 0.250″ gland size for smaller cables. The PDF documentation provides precise measurements for both, enabling accurate selection. Understanding this correlation is vital, as an improperly sized gland can compromise the cable’s environmental protection.

Always consult the T&B PDF to verify compatibility, especially when dealing with different cable jacket diameters. Correct gland size selection prevents cable strain and maintains the integrity of the weatherproof seal, crucial for long-term reliability.

Star Teck vs. Star Teck XP Connectors

T&B’s PDF documentation details the distinctions between Star Teck (ST Series) and Star Teck XP (STX Series) connectors, impacting cable compatibility and application suitability. While both serve the same fundamental purpose – secure termination of Teck cable – the XP series offers enhanced features.

The primary difference lies in the jacket grip mechanism. Star Teck connectors utilize a standard grip, while Star Teck XP employs an improved design for a more robust hold, particularly beneficial for demanding environments. The PDF charts illustrate specific part numbers for each series, categorized by cable size (e.g., 14/8, 14/10, 12 AWG).

Selecting the appropriate series depends on the application’s requirements. For general-purpose installations, Star Teck suffices, but for critical applications or where vibration is a concern, Star Teck XP is recommended. Always refer to the T&B PDF for detailed specifications and compatibility information.

Detailed T&B Teck Connector Size Chart (Examples)

T&B’s comprehensive PDF charts provide specific connector part numbers, hub sizes, and gland sizes for various Teck cable configurations, simplifying selection.

14/8 Teck Cable Connector Sizes (T&B 10465-TB)

For 14/8 Teck cable utilizing the T&B 10465-TB connector, detailed sizing information is readily available within T&B’s official PDF documentation. This specific connector commonly pairs with a 1/2” hub size, employing the ST050-466 Star Teck style or the STX075-466 Star Teck XP variant.

The corresponding gland size is crucial for a secure seal; referencing the PDF ensures compatibility. STE050 and STEX075 are also associated styles. It’s important to note that suggested cable sizes can vary slightly based on the specific cable manufacturer’s specifications, so always cross-reference.

T&B’s charts clearly outline the cable opening range, ensuring proper accommodation. These PDF resources are essential for installers, providing a precise guide to avoid improper fittings and maintain cable integrity. Proper selection guarantees adherence to relevant CSA standards and UL file numbers (E 23018).

14/10 Teck Cable Connector Sizes

Selecting the correct connector for 14/10 Teck cable requires consulting the comprehensive T&B PDF size charts. Typically, a 3/4” hub size is recommended for this cable configuration. The associated Star Teck style is often designated as ST075-466, while the Star Teck XP equivalent is STX100-466.

Detailed PDF documentation outlines compatible gland sizes for a watertight seal, crucial for reliable performance. Remember that cable manufacturer specifications can influence optimal connector choice, so verification is key. T&B provides extensive resources to aid in this process.

These charts also detail the cable opening ranges, ensuring proper accommodation and preventing damage. Adhering to T&B’s guidelines, found within their PDFs, guarantees compliance with CSA standards (CSA C22.2 No. 18) and UL file numbers (E 23018), ensuring a safe and code-compliant installation.

12 AWG Teck Cable Connector Sizes (T&B 10601-TB & 10602-TB)

T&B’s PDF size charts indicate that 12 AWG Teck cable commonly utilizes either the 10601-TB or 10602-TB connectors. The 10601-TB typically pairs with a 3/4” hub size, offering a gland size of approximately 0.625” to 0.760” with a 0.615” cable opening.

Conversely, the 10602-TB connector is generally suited for a 1” hub size, featuring a 0.750” gland size. These specifications, detailed in the official T&B PDF documentation, are vital for ensuring a secure and weatherproof connection.

Always cross-reference with the cable manufacturer’s data sheet, as slight variations may necessitate adjustments. Compliance with CSA C22.2 No. 18 and UL File E 23018 is confirmed through proper connector selection, as outlined in T&B’s comprehensive resources. Careful review of the PDFs is crucial for a successful installation.

Teck Connector Specifications & Standards

T&B Teck connectors adhere to rigorous CSA C22.2 No. 18 and UL File E 23018 specifications, detailed in their PDF guides, ensuring safety and reliability.

CSA Standards for Teck Cable (CSA C22.2 No. 18)

CSA C22.2 No. 18, the Safety Standard for Type Teck Cable, is paramount when selecting T&B connectors. This standard, comprehensively outlined in T&B’s downloadable PDF documentation, dictates the performance and safety requirements for these cable systems. It covers aspects like flame retardancy, moisture resistance, and mechanical strength – all critical for reliable operation in diverse environments.

Understanding the standard’s cable opening range, such as the .485.660 range for 253-I-TB connectors, is vital for proper fit and sealing. The PDF resources from T&B detail how connector selection aligns with specific cable constructions and sizes. Compliance with CSA C22.2 No. 18 ensures that the complete Teck cable assembly, including the connectors, meets recognized safety benchmarks. This is especially important for installations requiring regulatory approval and long-term dependability.

Referencing the latest version of the standard within the T&B PDFs guarantees adherence to current safety protocols and best practices.

UL File Numbers for T&B Teck Connectors (E 23018)

T&B Teck connectors are rigorously evaluated and listed under UL File Number E 23018, signifying compliance with stringent safety and performance criteria. This UL listing, detailed within T&B’s comprehensive PDF documentation, assures users of product reliability and suitability for intended applications. The file number confirms that the connectors have undergone testing for electrical safety, mechanical durability, and resistance to environmental factors.

Accessing the UL listing information through T&B’s PDFs provides valuable insights into the specific standards met by each connector model. This is crucial for projects requiring UL-recognized components, particularly in industries with strict regulatory requirements. The PDFs often cross-reference connector part numbers with their corresponding UL classifications, simplifying the selection process.

Verification of the UL listing (E 23018) via T&B’s resources ensures that the connectors meet North American safety standards and contribute to a safe and compliant installation.

Hazardous Location Specifications

T&B Teck connectors designed for hazardous locations adhere to specific specifications outlined in detailed PDF documentation. These connectors are engineered to prevent ignition of flammable gases or dusts, ensuring safety in potentially explosive environments. The PDFs detail suitability for Class I, Division 1 & 2, and Class II, Division 1 & 2 locations, alongside appropriate temperature codes.

Selecting the correct connector requires careful consideration of the hazardous location classification and the cable size. T&B’s PDFs provide guidance on compatible connectors for various hazardous area applications, referencing relevant standards and certifications. Suggested specifications for metal-clad cable or Teck cable fittings are clearly presented.

Always consult the T&B PDFs to verify connector suitability for the specific hazardous location and ensure compliance with local regulations. Proper connector selection is paramount for maintaining a safe operating environment.

Teck Connector Trade Sizes & Ranges

T&B Teck fittings, detailed in their PDF charts, span 1/2″ to 4″ NPT trade sizes, accommodating cables from 0.500″ to 4.330″ in diameter.

Available Trade Sizes (1/2″ to 4″)

T&B offers a comprehensive range of Teck connectors, meticulously documented in their downloadable PDF catalogs, covering trade sizes from 1/2″ to 4″. This extensive selection ensures compatibility with a vast array of cable diameters commonly used in industrial and commercial applications.

The 1/2″ trade size is frequently utilized for smaller diameter Teck cables, while the larger 3″ and 4″ sizes are reserved for substantial cable runs requiring increased protection and support. Detailed charts within the PDFs specify the exact cable diameter ranges each trade size can accommodate, preventing improper fittings and ensuring a secure, weatherproof seal.

Understanding these trade sizes is crucial for accurate project planning and material procurement. T&B’s PDF resources provide clear, concise information, enabling engineers and installers to select the optimal connector for their specific Teck cable application. Proper size selection guarantees compliance with relevant safety standards and maximizes the longevity of the installation.

Overlapping Size Ranges for Cable Accommodation

T&B’s Teck connector design philosophy, detailed within their comprehensive PDF documentation, incorporates overlapping size ranges to enhance cable accommodation flexibility. This strategic approach minimizes the need for an exhaustive inventory of connector sizes, streamlining procurement and reducing potential delays.

The PDF charts illustrate how a single connector trade size can often accept a range of cable diameters, providing installers with a buffer for slight variations in cable manufacturing. This overlap is particularly beneficial when working with cables from different manufacturers, each potentially exhibiting minor dimensional differences.

However, it’s crucial to consult the PDF specifications to confirm compatibility, as exceeding the recommended cable diameter can compromise the connector’s sealing capabilities. T&B’s documentation clearly outlines these acceptable ranges, ensuring a secure and reliable connection. Utilizing this overlapping size feature effectively optimizes inventory management and simplifies installation processes.

Finding the Right Teck Connector – Resources

Access detailed T&B Teck connector PDFs, including comprehensive size charts, on the official T&B website for accurate selection and specifications.

T&B Official Documentation & PDFs

Thomas & Betts (T&B) provides extensive documentation, readily available as PDF downloads, to assist in selecting the correct Teck connectors. These resources are crucial for ensuring compatibility between cable size and connector specifications, adhering to both CSA and UL standards.

Key documents include detailed size charts outlining hub sizes, gland sizes, and corresponding cable ranges for both Star Teck and Star Teck XP connectors; You’ll find specific part numbers like 10465-TB, 10601-TB, and 10602-TB clearly referenced alongside their applicable cable diameters.

PDFs also cover hazardous location specifications and provide information on CSA C22.2 No. 18 and UL File E 23018 compliance. These documents detail overlapping size ranges, allowing for accommodation of various cable manufacturers’ specifications. Accessing these official resources guarantees accurate installation and adherence to safety regulations, simplifying the connector selection process.

Where to Purchase T&B Teck Connectors

T&B Teck connectors are widely available through a network of authorized distributors and electrical supply houses. While direct purchase from T&B may be possible, leveraging their distributor network often provides competitive pricing and convenient local access.

Major electrical distributors, such as Rexel, Graybar, and CED, typically stock a comprehensive range of T&B connectors, including those detailed in the official PDF size charts. Online marketplaces like Amazon and specialized electrical supply websites also carry T&B products, offering a convenient purchasing option.

When ordering, referencing the specific part number (e.g., 10465-TB, 10601-TB) and verifying compatibility with your Teck cable size is crucial. Consulting the T&B documentation ensures you acquire the correct connector for your application, adhering to CSA and UL specifications. Always purchase from reputable sources to guarantee product authenticity and quality.

Leave a Reply